How the System Works
A walk through a ROSSMA installation: what is mounted on the pipe, how the data travels and how a pressure drop becomes an alarm with a location.
From the Pipe to the Control Room
Five links, all supplied and supported by ROSSMA
ROSSMA Pressure Sensors
Battery-powered wireless sensors on the existing pressure taps along the route. They check the pressure every 5 seconds and send it by radio.
Collects the radio packets of every sensor within up to 15 km and passes them on over 4G or Ethernet.
Authenticates every device, decrypts the AES-128 traffic and routes the data to the platform over MQTT.
Analyses the data around the clock: pressure-wave detection, machine-learning checks, leak location, alarms and reports — in our cloud or on your servers.
Push, e-mail, Telegram and SMS reach the control room and the field crew within seconds.
Primary Sensor — IIOT-AMS P-METER
A self-contained, explosion-proof pressure sensor with its own battery — the part of the system that sees the leak first.
- Pressure Range
- 0–7 / 0–10 / 0–20 / 0–35 / 0–70 MPa
- Accuracy
- ±0.2%
- Protocol
- LoRaWAN Class A (OTAA/ABP)
- Frequency
- 868 MHz (RU868 / EU868)
- Communication Range
- Up to 5 km (urban) / 15 km (rural, line-of-sight)
- Encryption
- AES-128 (LoRaWAN standard)
- Battery Life
- Up to 10 years (3.6V LiSOCl₂, 14 Ah)
- Measurement Capacity
- >1,000,000 readings per battery
- Background Monitoring
- Every 5 sec (local comparison, no radio transmission)
- Alarm Transmission
- Instant upon threshold exceedance
- Scheduled Transmission
- Every 15 min (configurable from 1 min)
- Measurement Time
- ≤2 sec (fast mode: 0.5 sec)
- Operating Temperature
- −55°C to +80°C
- Media Temperature
- −40°C to +125°C
- Explosion Protection
- 1Ex db IIC T5 Gb X / PB Ex db I Mb X
- Ingress Protection
- IP66
- Housing
- Aluminum A356 or Stainless Steel AISI 316
- Sensing Element
- Stainless Steel 316L
- Dimensions
- 260 × 130 × 70 mm
- Weight
- ≤1.5 kg
- Built-in Temperature Sensor
- Yes
- Calibration Interval
- 3 years
- MTBF
- 180,000 hours
- Service Life
- ≥20 years
TR CU 012/2011 (valid until 2 December 2030), dual Ex certification
How the Sensor Works Between Packets
Background Check
Wakes every 5 seconds and compares the pressure with its limits on board, without using the radio, so the battery lasts for years.
Alarm Packet
Sends at once when the pressure leaves its limits, so the platform learns of the drop within seconds.
Regular Packet
Every 15 minutes it sends the full reading for trends, analytics and training the models.
Full Technical Specifications
Ways to Connect Your Line
Use new ROSSMA sensors, or bring the instruments you already have onto the platform
ROSSMA Wireless Pressure Sensor
New installations where accuracy and battery life matter most
4–20 mA to LoRaWAN Converter, 1 channel
You already have 4–20 mA pressure transmitters and only need the radio link
4–20 mA to LoRaWAN Converter, 4 channels
Well pads and nodes with four measuring points close together
ROSSMA IIOT-AMS Modbus
Existing flow meters with RS-485 Modbus RTU
Starter Kit
A ready set — sensor, base station and platform access — for a first section
What Goes on Site
The equipment of a typical installation
Wireless pressure sensor
Measures pressure at the control points
Usually one every 5–15 km
Temperature sensor (optional)
Temperature compensation and extra analysis
1 per node, if needed
Sharpens the leak location
LoRaWAN base station
Receives the sensor data and forwards it
1 per 15 km of coverage
IP67; can run off-grid
Internet link
Connects the base station to the platform
4G modem or Ethernet
Solar power kit (optional)
Powers a base station without mains
Where there is no grid
Panel and battery pack
What Happens When the Pipe Leaks
Step by step, from the pressure drop to the alarm
Measuring all the time
The sensors check the pressure every 5 seconds and notice a crossing of the limits at once.
Radio link
The AES-128 encrypted packet reaches the nearest base station over LoRaWAN, up to 15 km away.
Into the platform
The base station passes it over 4G or Ethernet to the network server, which hands it to the platform over MQTT.
Six methods at once
Negative pressure wave, pressure gradient, mass balance, machine-learning anomaly, ΔP threshold and statistical tests run in parallel.
Placing the leak
The pressure drop and the arrival times of the wave at the sensors place the leak on a stretch of the line; precise time stamps and denser sensors narrow it to tens of metres.
The alarm goes out
As soon as the event is confirmed the control room and the crew receive the map position, the severity and what to do next — by push, e-mail, Telegram and SMS.
From the leak to the alarm for a medium leak: 10 minutes on an oil or gas pipeline, 30 on a heating network, 60 on a water main
How It Compares
ROSSMA against the usual ways of finding leaks
ROSSMA sensors and platform
10–60 min by network type
Section; tens of metres with precise timing
Low: subscription plus wireless sensors
Any length — add base stations
Fibre-optic sensing (DTS)
Very high capital cost per km
Only where the cable runs
SCADA with wired instruments
High: cabling and installation
Only the wired points
Patrols and inspections
Along the patrol route
Acoustic sensors
Plan the Network First
Before any hardware is ordered, the free ROSSMA Network Planner works out how many sensors and base stations your line needs and where to put them.
- Sensor spacing from the pipe diameter and pressure
- Base station positions for full LoRaWAN coverage
- An equipment list with a cost estimate