Thermal Analysis

Thermal analysis follows the temperature along each pipeline, finds sections at risk of freezing and recommends heating. It runs in the background and checks every active pipeline every 15 minutes.

Ground Temperature

Ground temperature at the depth of the pipe is estimated with a sinusoidal model that accounts for the damping and the delay of the seasonal wave with depth; where available, real weather data from Open-Meteo is used.

Ground Temperature Equation

Freeze Risk

The platform calculates the product temperature along the whole line and marks the sections where it falls below the critical levels.

The product is well above freezing

The product is approaching freezing

Watch more closely and prepare the heating

The product is at or close to freezing

Switch on the trace heating; consider increasing the flow

The product is below freezing

Emergency: act at once

Temperature Profile

The temperature of the product along the line is calculated from:

heat lost to the ground, from the depth of cover and the soil

the insulation of each section

trace heating, where it is installed

changes of elevation along the route

Temperature Alarms

The thermal alarm service raises alarms and notifications by itself:

a background check of every active pipeline every 15 minutes

repeated alarms of the same kind are merged within 2 hours, so nobody is flooded

e-mail notifications for critical freeze risk

the alarms go through the platform’s alarm system for acknowledgement and closure