Sensor Setup

Sensors the Platform Uses

The main detection sensor: pipeline pressure for the pressure-wave and pressure-drop methods.

Volumetric or mass flow for the mass balance.

Product and ambient temperature for thermal analysis and freeze risk.

Mechanical vibration that may come from a leak or from failing equipment.

Liquid level in tanks, sumps and open channels.

LoRaWAN Settings

Sensors communicate via LoRaWAN through an IIOT-NETS network server. The platform receives uplink events via MQTT and automatically decodes the payload.

Every sensor is identified by its DevEUI, a unique 16-character hexadecimal code

IIOT-NETS publishes uplink events to MQTT topic: application/{app_id}/device/{dev_eui}/event/up

The platform receives the uplinks from the network server over MQTT

The payload is decoded by the codec of the device profile in the device catalogue

An Uplink Event

Where to Put the Sensors

Where the sensors stand decides how closely a leak can be placed: the closer they stand and the nearer they reach to the ends of the line, the shorter the stretch the platform names.

For the pressure-wave method, install pressure sensors in pairs along the line at regular intervals

Usual spacing: 1–5 km on water pipelines, 5–20 km on oil and gas pipelines

Add sensors at junctions, at changes of elevation and in high-risk areas

Make sure each sensor reaches a LoRaWAN base station reliably

How closely the pressure wave places a leak depends on the sensor spacing and on how precisely the sensors time-stamp the wave: closer spacing and synchronised time stamps narrow the zone.

Calibration and Thresholds

Enter the accuracy of each sensor, and the platform calculates its detection threshold from it.

Manual detection threshold (bar), overriding the calculated one

Sensor accuracy as a percentage of full scale

Sensor accuracy in bar

Lower end of the measuring range (bar)

Upper end of the measuring range (bar)