Several detection methods run side by side, each on its own. A weighted decision engine combines their results, so that a real leak is confirmed by more than one sign and a single noisy method does not decide alone.

Pressure Drop

Every new pressure reading is compared with the previous reading of the same sensor. If the fall is larger than the threshold, a leak event is opened.

How the Threshold Is Set

The threshold follows from the accuracy of the sensor, so a precise sensor reacts to smaller drops than a coarse one. The platform takes the first value available from this chain:

Order of Precedence

The threshold multiplier (3.0 by default) is set in Settings > Detection Configuration.

Negative Pressure Wave

A leak makes the pressure fall suddenly at one point, and the fall travels along the pipe in both directions as a negative pressure wave. The moments it reaches the sensors tell the platform where it started — the more precisely the sensors time the wave, the closer. With periodic readings the platform names a stretch of the line by the size of the drop and narrows it a few minutes later by the settled pressures.

The Location Formula

Where the Leak Is

The Speed of the Wave

How fast the wave travels depends on the product and the pipe. The platform works it out with the Korteweg equation from the parameters of the pipeline.

Korteweg Equation

Combining the Methods

The detection service runs all the methods and weighs their results: each method reports a confidence, which is multiplied by its weight, and the products are combined into the final confidence of the event.

Arrival times of the pressure wave, used to place the leak

How far the pressure profile departs from the expected steady gradient

Flow in against flow out for each section

Machine-learning anomaly detection on the pressure patterns

Checking and Classifying an Event

After an event is opened, the verification service follows the pressure for a set window (10 minutes by default) and classifies the event by how the pressure behaves:

The pressure falls and stays below its normal level

Pressure stays low; several sensors show the same lasting drop

Suspected Illegal Tap

A drop, an overshoot (water hammer) and partial recovery

The pressure overshoots its normal level, and nearby sensors see the same

A slow downward trend on several sensors

A falling pressure trend that several sensors share

Quick recovery, nothing on the neighbours

The pressure recovers within seconds, the first confidence was low, the neighbouring sensors saw nothing

Verification runs in the background and does not slow down the processing of each reading. Its settings are part of the detection configuration.