Negative Pressure Wave Leak Location: The Physics and the Limits

When a pipe wall fails, the pressure at that point drops at once, and the drop does not stay there. It travels away from the leak in both directions as a wave — the negative pressure wave (NPW). Sensors upstream and downstream see it arrive at slightly different moments, and that difference tells you where the leak is. This article explains the physics, the formula, and — just as important — what really limits the accuracy.

How Fast the Wave Travels

The wave moves at the speed of sound in the product, slowed down by the elasticity of the pipe wall. Typical values:

ProductWave speed
Water1,000–1,400 m/s
Crude oil800–1,200 m/s
District heating water1,100–1,300 m/s, depending on temperature
Natural gas300–400 m/s

The speed in a particular pipe follows the Korteweg equation:


c = c_fluid / sqrt(1 + (K_fluid * D) / (E_pipe * e))

The ROSSMA platform calculates c for every section from the parameters you enter — material, diameter, wall and product — so the operator does not have to measure it before the first alarm.

Where the Leak Is

Take two sensors, A and B, a distance L apart. If the wave reaches A at t_A and B at t_B, with Δt = t_B − t_A:


x = (L − c · Δt) / 2

x is the distance from sensor A to the leak. If A sees the wave first, Δt is positive and the leak lies closer to A.

What Really Limits the Accuracy

The formula is exact; the inputs are not. The error in the position comes almost entirely from how precisely each sensor knows when the wave front passed it. If the two sensors are wrong by e₁ and e₂ seconds:


|error| ≤ c · (e₁ + e₂) / 2

At 1,400 m/s, the same timing error gives:

Timing error at each sensorError in the leak position
1 sup to ±1,400 m
100 msup to ±140 m
50 msup to ±70 m
20 msup to ±28 m

Two things set the timing error:

So the honest answer to "how accurate is NPW?" is: as accurate as the timing of your sensors. With battery sensors that check the pressure every few seconds the platform names a stretch of the line by the size of the pressure drop and narrows it a few minutes later by the settled pressures — kilometres on a long line — which already tells the crew where to go. Sensors that sample many times a second and time-stamp the front to tens of milliseconds bring that down to tens of metres. The ROSSMA platform accepts both: periodic readings, event records with millisecond time stamps, and continuous streams from mains-powered sensors.

What Else Gets in the Way

How It Compares

MethodDetectionLocation
Negative pressure waveseconds to minutesfrom a stretch of the line down to tens of metres, depending on timing
Mass balancean hour or morethe section only
Acousticseconds to a minute±100 m within sensor reach
Fibre-optic sensingminutesa few metres, where the cable runs

The wave method's strength is that it needs no cable along the route and works on existing, buried pipelines: the sensors mount on the pressure taps that are already there.